Product List
Plug Fans

- APF-50BL
- APF-56BL

BLDC Double Inlet Fans

- ECA-110BL
- ECA-111BL
- ECA-122BL
- ECA-133BL
- ECA-910BL
- ECA-980BL
- ECA-1512BL

Double Inlet Fans (Constant Temperature & Humidity)

- AS-110D (6 POLE)
- AS-110D (8 POLE)
- AS-111D (6 POLE)
- AS-111D (8 POLE)
- AS-122D (6 POLE)
- AS-122D (8 POLE)
- AS-133D (6 POLE)
- AS-133D (8 POLE)
- AS-430D (4 POLE)
- AS-660D (4 POLE)
- AS-780D (4 POLE)
- AS-880D (4 POLE)
- AS-880D (6 POLE)
- AS-910D (4 POLE)
- AS-910D (6 POLE)
- AS-910D (8 POLE)
- AS-1512D (6 POLE)
- AS-1512D (8 POLE)

Portable Welding Fume Precipitators

- AWD-300C
- AWD-300S
- AWD-300T

Airfoil Fans

- ABA-037SD ("A" TYPE)
- ABA-037SD ("B" TYPE)
- ABA-037SD ("C" TYPE)

Roof Ventilators

- KRF-022BH

S-Blade Square Fans

- ASF-304
- ASF-404
- ASF-504
- ASF-506
- ASF-604
- ASF-606
- ASF-704
- ASF-706
- ASF-804
- ASF-806
- ASF-906

Centrifugal Turbo Blowers

- ATT-024-002
- ATT-025-004
- ATT-030-007
- ATT-034-010
- ATT-036-012
- ATT-038-015
- ATT-045-017
- ATT-048-020

In-Line Duct Fans

- AD-010-020
- AD-015-020
- AD-020-040
- AD-025-040
- AD-030-040
- AD-035-040
- AD-035-060
- AD-025-020S
- AD-030-020S

V-Belt Drive Single-Type Centrifugal Fans

- V-AS110DX1
- V-AS122DX1
- V-AS155DX1
- V-AS188DX1

V-Belt Drive Twin-Type Centrifugal Fans

- V-AS110DX2
- V-AS122DX2
- V-AS155DX2
- V-AS188DX2

Box-Type Fans

- BB-AS110D6
- BB-AS122D6
- BB-AS133D6
- BB-AS133D8
- BB-AS1512D8
- BB-AS1512D6
- BB-AS880D4
- BB-AS910D4
- BB-AS910D6

Double Inlet Twin Fans

- AT-010-060
- AT-010-080
- AT-012-060
- AT-012-080
- AT-013-060
- AT-013-080
- AT-015-080
- AT-060-040
- AT-070-040
- AT-080-040
- AT-090-040

Constant-Pressure Duct Fans

- ATP-0680-040
- ATP-0780-040
- ATP-0880-040
- ATP-0980-040

Single-Inlet Fans

- AS-0104S
- AS-0124S
- AS-0310S
- AS-0415S
- AS-0525S
- AS-0625S
- AS-0730S
- AS-0830S
- AS-0930S

Outer Rotor Single-Inlet Direct-Drive Centrifugal Fans (AC)

- AOS2S-120-60A
- AOS2S-133-60A
- AOS2S-145-60A
- AOS2S-160-60A
- AOS2S-180-75A
- AOS4S-145-60A
- AOS4S-160-60A
- AOS4S-180-75A
- AOS4S-180-90A
- AOS4S-200-100A

Outer Rotor Single-Inlet Direct-Drive Centrifugal Fans (BLDC)

- ABS2D-145-150A
- ABS2D-185-100A
- AOS2S-145-60A
- AOS2S-160-60A
- AOS2S-180-75A

Outer Rotor Backward-Curved Fans (AC)

- AOB2S-190-45A
- AOB2S-225-50A
- AOB2S-250-52A
- AOB2S-280-50A
- AOB4S-190-45A
- AOB4S-225-50A
- AOB4S-250-52A
- AOB4S-280-50A

Outer Rotor Backward-Curved Fans (BLDC)

- AOB2S-190-45A
- AOB2S-225-50A
- AOB2S-250-52A

Outer Rotor Double-Inlet Direct-Drive Centrifugal Fans

- AOS2D-120-126A
- AOS2D-133-150A
- AOS2D-145-150A-1
- AOS2D-145-150A-2
- AOS4D-145-200A
- AOS2D-160-160A
- AOS4D-133-200A
- AOS4D-145-200A
- AOS4D-160-200A
- AOS4D-180-180A

Cross-Flow Fans

- AC-045-020
- AC-060-010
- AC-060-020
- AC-060-030
- AC-060-040
- AC-060-050
- AC-090-070
- AC-097-030
- AC-097-040
- AC-097-050
- AC-097-060

Elevator Ventilation Fans

- AC-097-030E
- AC-097-040E
- AC-097-050E

Cross-Flow Cooling Fans

- AC-150B
- AC-150C
- AC-150D

Power Ventilators
Hanger Fans for Underground Parking Lots

- ASHF-5000
- ASHF-7500
- ASHF-10000
- ASHF-15000
- ASHF-20000
- ASHF-25000
- ASHF-30000
- ASHF-35000
- ASHF-40000
- ASHF-45000
- ASHF-50000

Fan Filter Units (FFU)

- KJ FFU-A TYPE
- KJ FFU-B TYPE
- KJ FFU-C TYPE
- KJ FFU-D TYPE

Standard Air Curtains

- KAC-120-1000
- KAC-120-1200
- KAC-120-1500
- KAC-120-2000
- KAC-120-900

Standard Air Curtains (Heater Type)

- ACH-120-1000
- ACH-120-1200
- ACH-120-900

Standard Air Curtains (Filter Type)

- KAC-120-1000F
- KAC-120-1200F
- KAC-120-1500F
- KAC-120-900F

Commercial Air Curtains

- AC-150-1000
- AC-150-1200
- AC-150-900

Industrial Air Curtains

- ACI-780-1000
- ACI-780-1200
- ACI-780-1500
- ACI-780-900

Traction Motor Blowers
Motor Block Blowers
Auxiliary Block Blowers
Main Transformer Blowers
Sirocco Impellers
Turbo Impellers
Impellers
 

CROSS FLOW FANS

Category
CROSS FLOW
CROSS FLOW FANS

CROSS FLOW FANS

Characteristics

  • With uniform distribution of airflow per length, excellence in operation with lower level of noise achived
  • With less vortex generation, excellent function in reaching distance ensured
  • Specifications available to be customized in accordance to customer’s order request. (RPM 2-8 poles)
  • Various models available per size of the product

CROSS FLOW FANS – Kyungjin Blower

Models & Data ( Click to unfold)

AC-045-020  Static Pressure: 24.5Pa (2.5mmAq)  Air Volume: 1.6m³/min
AC-060-010  Static Pressure: 39.2Pa (4.0mmAq)  Air Volume: 2.0m³/min
AC-060-020  Static Pressure: 39.2Pa (4.0mmAq)  Air Volume: 3.1m³/min
AC-060-030  Static Pressure: 39.2Pa (4.0mmAq)  Air Volume: 4.2m³/min
AC-060-040  Static Pressure: 39.2Pa (4.0mmAq)  Air Volume: 5.8m³/min
AC-060-050  Static Pressure: 39.2Pa (4.0mmAq)  Air Volume: 6.5m³/min
AC-090-070  Static Pressure: 58.8Pa (6.0mmAq)  Air Volume: 14.1m³/min
AC-097-030  Static Pressure: 58.8Pa (6.0mmAq)  Air Volume: 5.0m³/min
AC-097-040  Static Pressure: 58.8Pa (6.0mmAq)  Air Volume: 7.0m³/min
AC-097-050  Static Pressure: 58.8Pa (6.0mmAq)  Air Volume: 8.5m³/min
AC-097-060  Static Pressure: 58.8Pa (6.0mmAq)  Air Volume: 9.5m³/min