HANGER FANS FOR UNDERGROUND PARKING LOT

HANGER FANS FOR UNDERGROUND PARKING LOT

HANGER FANS FOR UNDERGROUND PARKING LOT

Characteristics

  • Fan and louvers integrated in a single cabinet for ease of handling and installation
  • Compared to conventional large diameter duct, height of the fan lowered by diversely distributed fan, thus possible to be installed on the ceiling
  • Construction fee reduced due to unnecessary separate room for fan
  • Lower electricity consumed due to the adoption of highefficiency motors

HANGER FANS FOR UNDERGROUND PARKING LOT – Kyungjin Blower

Models & Data ( Click to unfold)

ASHF-5000 (V-belt)   Motor Power: 1.50kW (2.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 83.33m³/min
ASHF-5000 (Direct)   Motor Power: 1.12kW (1.5HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 83.33m³/min
ASHF-7500 (V-belt)   Motor Power: 1.50kW (2.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 125.00m³/min
ASHF-7500 (Direct)   Motor Power: 1.12kW (1.5HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 125.00m³/min
ASHF-10000 (V-belt)  Motor Power: 2.20kW (3.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 166.67m³/min
ASHF-10000 (Direct)  Motor Power: 2.20kW (3.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 166.67m³/min
ASHF-15000 (V-belt)  Motor Power: 2.20kW (3.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 250.00m³/min
ASHF-15000 (Direct)  Motor Power: 3.70kW (5.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 250.00m³/min
ASHF-20000 (V-belt)  Motor Power: 3.70kW (5.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 333.33m³/min
ASHF-25000 (V-belt)  Motor Power: 5.50kW (7.5HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 416.67m³/min
ASHF-30000 (V-belt)  Motor Power: 7.50kW (10.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 500.00m³/min
ASHF-35000 (V-belt)  Motor Power: 7.50kW (10.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 583.33m³/min
ASHF-40000 (V-belt)  Motor Power: 7.5k0W (10.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 666.67m³/min
ASHF-45000 (V-belt)  Motor Power: 7.50kW (10.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 750.00m³/min
ASHF-50000 (V-belt)  Motor Power: 11.0kW (15.0HP)  Static Pressure: 98~47Pa (10~15mmAq)  Air Volume: 833.33m³/min